Power is the rate of using energy. For electricity:
P = VI = I²R = V²/R
The unit is the watt (W): 1 W = 1 V × 1 A. A bigger unit is the kilowatt (1 kW = 1000 W).
Energy = power × time, so energy can be measured in watt hours. The commercial unit is the kilowatt hour (kW h), the 'unit' on your electricity bill:
1 kW h = 1000 W × 3600 s = 3.6 × 10⁶ J
More to know: electrons are not used up in a circuit. We pay the electricity company for the energy that moves electrons through our bulbs, fans and motors.
Examples: a bulb on 220 V taking 0.50 A: P = 110 W. A 400 W fridge running 8 h a day for 30 days uses 400 × 8 × 30 = 96 000 W h = 96 kW h; at ₹3.00 per unit that costs ₹288.
An iron draws 840 W at its hottest on 220 V: I = 840/220 ≈ 3.82 A, R ≈ 57.6 Ω. At 360 W: I ≈ 1.64 A, R ≈ 134 Ω.