Power reaches homes through the mains, by overhead poles or underground cables. In India it is AC at 220 V and 50 Hz.
| Wire | Insulation | Job |
|---|---|---|
| live (positive) | red | carries the supply |
| neutral (negative) | black | return path; 220 V between live and neutral |
| earth | green | safety, joined to a metal plate deep in the ground |
At the meter board the wires pass a main fuse, then the electricity meter, then a distribution box with the main switch and a fuse for each circuit.
Often there are two circuits: a 15 A circuit for high-power appliances (geysers, air coolers) and a 5 A circuit for bulbs and fans.
Appliances are joined in parallel across live and neutral, so each gets the same 220 V and has its own switch.
Earth wire: metal-bodied appliances (iron, toaster, table fan, fridge) have their body joined to earth. If current leaks to the body, the earth wire gives it a low-resistance path, keeps the body at earth's potential, and the user does not get a severe shock.
Tap the diagram to enlarge it
- 220 V, 50 Hz AC
- 15 A and 5 A circuits
- Appliances in parallel